Eaton Managed rack PDU, 2U, L5-30P input, 2.88 kW max, 120V, 24A, 10 ft cord, Single-phase, Outlets: (16) 5-20R - Switched - NEMA L5-30P - 16 x NEMA 5-20R - 120 V AC - 2880 W - Network (RJ-45) - 2U - Horizontal - Rack-mountable
Eaton ePDU G3 Managed
Learn More
Eaton Managed ePDUs allow you to monitor and control critical factors such as voltage, current and power factor. This level of information allows you to make the right decision when it comes to energy consumption in your data center. Integrated with Eaton's management software, you can control these units from any computer on the network server.$879.64 -
Eaton Managed rack PDU, 2U, L6-30P input, 5.76 kW max, 200-240V, 24A, 10 ft cord, Single-phase, Outlets: (12) C13, (4) C19 - Switched - NEMA L6-30P - 12 x IEC 60320 C13, 4 x IEC 60320 C19 - 230 V AC - 5760 W - Network (RJ-45) - 2U - Horizontal - Rack-moun
Eaton ePDU G3 Managed
Learn More
Eaton Managed ePDUs allow you to monitor and control critical factors such as voltage, current and power factor. This level of information allows you to make the right decision when it comes to energy consumption in your data center. Integrated with Eaton's management software, you can control these units from any computer on the network server.$1,064.68 -
Eaton Managed rack PDU, 2U, L6-30P input, 5.76 kW max, 200-240V, 24A, 10 ft cord, Single-phase, Outlets: (16) C13 Outlet grip - NEMA L6-30P - 16 x IEC 60320 C13 - 230 V AC - 5760 W - Network (RJ-45) - 2U - Horizontal - Rack-mountable
Eaton Managed rack PDU, 2U, L6-30P input, 5.76 kW max, 200-240V, 24A, 10 ft cord, Single-phase, Outlets: (16) C13 Outlet grip - NEMA L6-30P - 16 x IEC 60320 C13 - 230 V AC - 5760 W - Network (RJ-45) - 2U - Horizontal - Rack-mountable Learn More$880.86 -
Eaton ePDU G3 EMAU25-10 24-Outlets PDU - Managed - 309-332P6W - 21 x IEC 60320 C13, 3 x IEC 60320 C19 - 230 V AC - Double Pole - 10 ft Cord Length - 2U - Rack-mountable
Eaton ePDU G3 EMAU25-10 24-Outlets PDU - Managed - 309-332P6W - 21 x IEC 60320 C13, 3 x IEC 60320 C19 - 230 V AC - Double Pole - 10 ft Cord Length - 2U - Rack-mountable Learn More$1,871.55 -
Eaton Metered Input rack PDU, 0U, 5-15P input, 1.44 kW max, 120V, 12A, 10 ft cord, Single-phase, Outlets: (24) 5-15R - NEMA 5-15P - 24 x NEMA 5-15R - 120 V AC - 1440 W - Network (RJ-45) - 38U - Rack-mountable
Eaton G3 Metered Input ePDUs provide a best-in-class design featureing billing grade accuracy monitoring of input and branch circuits on a local LCD pixel display or over a network connection. The high accuracy meter will measure current, voltage, power and energy for load balancing, capacity planning, efficiency monitoring and energy usage reporting. Designed for IT and data center applications means high reliability and a robust design made for high operating temperatures found in containment or networking closets.
- Advanced LCD pixel display for local display of current, voltage, power, energy and menu setup of parameters such as IP address or display rotation
- High operating temperature (140F / 60C) for containment or hot network closet environments
- Hot-swap meter for servicability of without removing power to the rack
- +/- 1% billing grade accuracy for high accuracy reporting of energy usage
- Daisy chain of IP addresses allows four devices to share one network connection
- Color coded outlet sections simplify load balancing
$546.04 -
Eaton Metered Input rack PDU, 0U, 5-20P, L5-20P input, 1.92 kW max, 120V, 16A, 10 ft cord, Single-phase, Outlets: (24) 5-20R - NEMA L5-20P - 24 x NEMA 5-20R - 120 V AC - 1920 W - Network (RJ-45) - 38U - Rack-mountable
Eaton G3 Metered Input ePDUs provide a best-in-class design featureing billing grade accuracy monitoring of input and branch circuits on a local LCD pixel display or over a network connection. The high accuracy meter will measure current, voltage, power and energy for load balancing, capacity planning, efficiency monitoring and energy usage reporting. Designed for IT and data center applications means high reliability and a robust design made for high operating temperatures found in containment or networking closets.
- Advanced LCD pixel display for local display of current, voltage, power, energy and menu setup of parameters such as IP address or display rotation
- High operating temperature (140F / 60C) for containment or hot network closet environments
- Hot-swap meter for servicability of without removing power to the rack
- +/- 1% billing grade accuracy for high accuracy reporting of energy usage
- Daisy chain of IP addresses allows four devices to share one network connection
- Color coded outlet sections simplify load balancing
$584.23